NESS M1 SINGLE DOOR ACCESS MODULE

Part Number : 101-246

or

Quick Overview

Single door access interface module for use on the M1 and M1EZ8 Control Panels.
ness-corporation-M1-single-door-access-module

More Views

  • ness-corporation-M1-single-door-access-module
 
 
  Description    Benefits    Technical Features    Downloads  

Description

 

A single door access interface module for use on the M1 and M1EZ8 Control Panels. The M1KAM connects to the 4 wire keypad data bus in place of a traditional M1 Keypad.

Since the maximum number of keypads on an M1 or M1EZ8 is 16, the maximum number of M1KAM modules (and controlled doors) is 16, minus any installed keypads.

Even though an M1 Keypad can accept a 26 bit access reader, the M1KAM is a more powerful and less expensive access solution. For example; the M1KAM includes a relay (door unlock) output with form "C" dry contacts, making it compatible with most door lock devices regardless of the voltage rating and style (AC or DC). The M1KAM accepts many types of card swipe or proximity readers conforming to the 26 bit wiegand format.

The M1KAM also has additional inputs and outputs, including: a request to exit (RTE) button or device and a Door Contact (Sensor) input. Both inputs are supervised with a 2,200 EOL resistor. Outputs on the M1KAM consists of a voltage output for Door Held Open Alarm, a voltage output for System Ready to Arm, and a voltage output for System Armed. These outputs are 12VDC (switched negative) and are rated for a maximum current of 50 milliamps.

The M1KAM is mounted in a universal surface mount plastic housing with knockouts for surface mount raceways.

Refer to Ness Access Control for a full range of Access Control Systems.

 

Note: This product requires firmware version 1.1.1 when using it with a 101-095.

 

Input for a 26 bit Wiegand Reader

 

Heavy Duty Form "C" Relay Contacts for Switching Door Strike Power

 

Low Current (50mA) 12VDC Output for Door Held Open Alarm

 

Low Current (50mA) 12VDC Output for System Ready To Arm indication

 

Low Current (50mA) 12VDC Output for System Armed indication

 

Supervised Input for RTE (Request To Exit) Button/Device

 

Supervised Input for Door Status Sensor

 

Installs in place of an M1 Keypad and operates from the RS-485 4-Wire Keypad Data Bus

 

Four selectable Time settings for "Request to Exit" and "Door Held Open"

 

Hardware Watchdog Circuit

 

Connections: Unpluggable Screw Terminals, 16 Position

 

Operating Voltage: 13.8 VDC

 

Current Draw: Less than 30 mA with min. activity, 44 mA fully active

 

Housing Dimensions: 4.25" x 6.375" x 2.125"

 

Circuit Board Dimensions: 3.95" W x 2.875" H x .95" D

 


INSTALLATION

MANUAL

Additional Information

Part Number 101-246

Product Tags